hpacucli 유틸리티

반응형

hpacucli 유틸리티

hpacucli 유틸리티를 사용하여 HP Smart Array 컨트롤러에서 RAID를 구성하는 예시입니다.

 

1. hpacucli 다운로드

wget http://downloads.linux.hp.com/SDR/downloads/ServicePackforProLiant/RedHatEnterpriseServer/5.7Server/x86_64/2013.02.0/hpacucli-9.40-12.0.x86_64.rpm
yum install hpacucli-9.40-12.0.x86_64.rpm

 

2. Array Card

hpacucli ctrl all show
$ hpacucli ctrl all show

Smart Array P400 in Slot 0 (Embedded)
Smart Array P800 in Slot 8 (sn: P98690K9SW20U7)

 

3. Logical Drive

hpacucli ctrl slot=0 ld all show
$ hpacucli ctrl slot=0 ld all show

Smart Array P400 in Slot 0 (Embedded)

   array A

      logicaldrive 1 (205.0 GB, RAID 1+0, OK)

 

4. Physical Drive

hpacucli ctrl slot=0 pd all show
$ hpacucli ctrl slot=0 pd all show

Smart Array P400 in Slot 0 (Embedded)

   array A

      physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 72 GB, OK)
      physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 72 GB, OK)
      physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 72 GB, OK)
      physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 72 GB, OK)
      physicaldrive 2I:1:3 (port 2I:box 1:bay 3, SAS, 72 GB, OK)
      physicaldrive 2I:1:4 (port 2I:box 1:bay 4, SAS, 72 GB, OK)
728x90

RAID 1 (Mirror) 구성 예시

  • RAID 1 구성을 위해 두 개의 물리 드라이브를 선택합니다.
hpacucli> ctrl slot=0 create type=ld drives=1:1,1:2 raid=1
  • 구성된 RAID 1의 세부 정보 표시
hpacucli> ctrl slot=0 ld all show detail

RAID 5 구성 예시

  • RAID 5 구성을 위해 세 개 이상의 물리 드라이브를 선택합니다.
hpacucli> ctrl slot=0 create type=ld drives=1:1,1:2,1:3,1:4 raid=5
  • 구성된 RAID 5의 세부 정보 표시
hpacucli> ctrl slot=0 ld all show detail

논리 드라이브 확장 (RAID 5에서 디스크 추가) 예시

  • RAID 5에서 디스크 추가
hpacucli> ctrl slot=0 ld 1 add drives=1:5
  • 확장된 RAID 5의 세부 정보 표시
hpacucli> ctrl slot=0 ld 1 show

 