HP Smart Array CLI commands

반응형

HP Smart Array CLI commands

Show configuration

/opt/hp/hpssacli/bin/hpssacli ctrl all show config

Controller status

/opt/hp/hpssacli/bin/hpssacli ctrl all show status

Show detailed controller information

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail

Rescan for New Devices

/opt/hp/hpssacli/bin/hpssacli rescan

Physical disk status

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status

Show detailed physical disk information

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail

Logical disk status

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status

View Detailed Logical Drive Status

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show

Create New RAID 0 Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0

Create New RAID 1 Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1

Create New RAID 5 Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5

Delete Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete

Add New Physical Drive to Logical Volume

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7

Add Spare Disks

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7

Enable Cache

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable

Disable Cache

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable

Erase Physical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase

Turn on Blink Physical Disk LED

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on

Turn off Blink Physical Disk LED

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off

Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0

Disable smart array cache for certain Logical Volume

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable

Enable smart array cache for certain Logical Volume

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable

Enable SSD Smart Path

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable

Disable SSD Smart Path

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable

 

출처

- https://www.inetmail.ca/Wiki/index.php/HP_Smart_Array_CLI_commands_on_ESXi#Controller_status

 

참고URL

- HP 서버 스토리지 정보 확인 : https://scbyun.com/856

 

728x90
반응형

'리눅스' 카테고리의 다른 글

[리눅스] Install Gitlab on CentOS  (0) 2015.09.14
[리눅스] git 설치(gitlab)  (0) 2015.09.11
[리눅스] itop(itsm) 설치하기  (0) 2015.08.19
HTTP Status Codes  (0) 2015.08.12
[linux] swap 메모리 초기화  (0) 2015.08.06